2.5 Adjustment Procedure

TOP PREVIOUS NEXT


Item / Preparation



Adjustment Procedure



+B Voltage


Confirm the DC voltage at the indicated test points, as follows :



1.
Operate the TV set.



TPA 12 : 140.5 ± 1.5V



2.
Set control as follows :



TPA 11 : 8 ± 1V




Brightness ...........minimum



TPA 10 : 5 ± 1V




Contrast .............. minimum





TPA 21 : 215 ± 15V



RF AGC






1.
Receive a colour bar signal at an RF level of 75 ± 1-2 dBU with 75Ω loaded.


1.
Select “RF AGC” indication in CHK2, on Screen by remote control at factory mode.



2.
Connect digital multimeter to RF AGC at Tuner.


2.
Set RF AGC by using remote control Volume (+) or Volume (-) button until voltage AGC at Tuner reaches 2.6 ± 0.1V at TPA 15 (Tuner point).







3.
Increase RF signal strength by 2dB, confirm AGC at Tuner voltage drop.





High Voltage






1.
Receive the crosshatch pattern.


1.
Connect a DC voltage meter to TPA 20 and confirm the +B voltage is 140.5 ± 1.5V.



2.
Set to 0 Beam.







Screen VR .......... minimum


2.
Connect a high frequency voltmeter to heater and confirm that voltage reads 6.0 ± 0.24 (VRMS).




Contrast .............. minimum










3.
Normalize the brightness and contrast.











Item / Preparation



Adjustment Procedure



NTSC TINT COLOUR






Connect a short jumper between TPA 10 and TPA 20.
Press Main Menu and set system to use AV-NTSC (3.58 MHz).
DYNAMIC ................. Normal
ChannelCLR Set ..... STD



1.
Adjust Sub-Tint so that No. 2, 3 and 4 becomes level waveform is similar to Fig. 3.





2.
Confirm phase at Tint is changes more than ± 30 by Tint control.





3.
Confirm that colour level is maximum when colour DAC is adjusted to maximum position.






Note: Use remote control only when adjusting user mode to Sub-Tint.













Fig. 3




TOP PREVIOUS NEXT