8.2 SERVICE POSITION
TOP PREVIOUS NEXT
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Be sure to discharge the capacitor on MAIN C.B.A. after removing the Rear case unit.
Refer to HOW TO DISCHARGE THE CAPACITOR ON MAIN C.B.A..
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
Be careful of the high voltage circuit on MAIN C.B.A.
DO NOT allow other parts to touch the high voltage circuit on MAIN C.B.A.
DO NOT PRESS AND BENT THE JUNCTION AREA OF MAIN C.B.A.
Since the Terminal board, Main board and Digital board of the Main C.B.A. are directly connected with Flexible Card, these junction areas are quite delicate.
Therefore, DO NOT hardly press and bent the junction areas of Main C.B.A.